Search results for "CdTe detectors"
showing 8 items of 8 documents
Performance of a digital CdTe X-ray spectrometer in low and high counting rate environment
2010
Abstract The high performances of CdTe detectors for X-ray and gamma ray spectroscopy are already well known. Among the traditional semiconductor spectrometers, CdTe detectors show high detection efficiency and good room temperature performance and are well suited for the development of compact detection systems. In this work, we investigated the performance of a CdTe detector coupled with a custom digital pulse processing (DPP) system for X-ray spectroscopy. The DPP method, implemented on a PC platform, performs a pile-up inspection and a pulse height analysis of the preamplifier output pulses, digitized by a 14-bit, 100 MHz ADC. The spectroscopic results point out the excellent performanc…
Direct Measurement of Mammographic X-Ray Spectra with a Digital CdTe Detection System
2012
In this work we present a detection system, based on a CdTe detector and an innovative digital pulse processing (DPP) system, for high-rate X-ray spectroscopy in mammography (1–30 keV). The DPP system performs a height and shape analysis of the detector pulses, sampled and digitized by a 14-bit, 100 MHz ADC. We show the results of the characterization of the detection system both at low and high photon counting rates by using monoenergetic X-ray sources and a nonclinical X-ray tube. The detection system exhibits excellent performance up to 830 kcps with an energy resolution of 4.5% FWHM at 22.1 keV. Direct measurements of clinical molybdenum X-ray spectra were carried out by using a pinhole…
High-rate x-ray spectroscopy in mammography with a CdTe detector: A digital pulse processing approach
2010
Purpose:Direct measurement of mammographic x-ray spectra under clinical conditions is a difficult task due to the high fluence rate of the x-ray beams as well as the limits in the development of high resolution detection systems in a high counting rate environment. In this work we present a detection system, based on a CdTe detector and an innovative digital pulse processing (DPP) system, for high-rate x-ray spectroscopy in mammography. Methods: The DPP system performs a digital pile-up inspection and a digital pulse height analysis of the detector signals, digitized through a 14-bit, 100 MHz digitizer, for x-ray spectroscopy even at high photon counting rates. We investigated on the respon…
Ballistic Deficit Pulse Processing in Cadmium-Zinc-Telluride Pixel Detectors for High-Flux X-ray Measurements.
2022
High-flux X-ray measurements with high-energy resolution and high throughput require the mitigation of pile-up and dead time effects. The reduction of the time width of the shaped pulses is a key approach, taking into account the distortions from the ballistic deficit, non-linearity, and time instabilities. In this work, we will present the performance of cadmium–zinc–telluride (CdZnTe or CZT) pixel detectors equipped with digital shapers faster than the preamplifier peaking times (ballistic deficit pulse processing). The effects on energy resolution, throughput, energy-linearity, time stability, charge sharing, and pile-up are shown. The results highlight the absence of time instabilities …
Charge Sharing and Cross Talk Effects in High-Z and Wide-Bandgap Compound Semiconductor Pixel Detectors
2023
Intense research activities have been made in the development of high-Z and wide-bandgap compound semiconductor pixel detectors for the next generation X-ray and gamma ray spectroscopic imagers. Cadmium telluride (CdTe) and cadmium-zinc-telluride (CdZnTe or CZT) pixel detectors have shown impressive performance in X-ray and gamma ray detection from energies of few keV up to 1 MeV. Charge sharing and cross-talk phenomena represent the typical drawbacks in sub-millimeter pixel detectors, with severe distortions in both energy and spatial resolution. In this chapter, we review the effects of these phenomena on the response of CZT/CdTe pixel detectors, with particular emphasis on the current st…
X-ray spectroscopy and dosimetry with a portable CdTe device.
2007
Abstract X-ray spectra and dosimetry information are very important for quality assurance (QA) and quality control (QC) in medical diagnostic X-ray systems. An accurate knowledge of the diagnostic X-ray spectra would improve the patient dose optimization, without compromising image information. In this work, we performed direct diagnostic X-ray spectra measurements with a portable device, based on a CdTe solid-state detector. The portable device is able to directly measure X-ray spectra at high photon fluence rates, as typical of clinical radiography. We investigated on the spectral performances of the system in the mammographic energy range (up to ∼40 keV). Good system response to monoener…
Development of a 3D CZT detector prototype for Laue Lens telescope
2010
We report on the development of a 3D position sensitive prototype suitable as focal plane detector for Laue lens telescope. The basic sensitive unit is a drift strip detector based on a CZT crystal, (similar to 19x8 mm(2) area, 2.4 mm thick), irradiated transversally to the electric field direction. The anode side is segmented in 64 strips, that divide the crystal in 8 independent sensor (pixel), each composed by one collecting strip and 7 (one in common) adjacent drift strips. The drift strips are biased by a voltage divider, whereas the anode strips are held at ground. Furthermore, the cathode is divided in 4 horizontal strips for the reconstruction of the third interaction position coord…
Performance enhancements of compound semiconductor radiation detectors using digital pulse processing techniques
2011
Abstract The potential benefits of using compound semiconductors for X-ray and gamma ray spectroscopy are already well known. Radiation detectors based on high atomic number and wide band gap compound semiconductors show high detection efficiency and good spectroscopic performance even at room temperature. Despite these appealing properties, incomplete charge collection is a critical issue. Generally, incomplete charge collection, mainly due to the poor transport properties of the holes, produces energy resolution worsening and the well known hole tailing in the measured spectra. In this work, we present a digital pulse processing (DPP) system for high resolution spectroscopy with compound …